Technetium MIBI May Help Clarify Some Inconclusive Mammogram

Publication
Article
Oncology NEWS InternationalOncology NEWS International Vol 4 No 7
Volume 4
Issue 7

BALTIMORE, Md--Both thallium-201 and technetium-99m are under study as agents for use in examining breast lesions for malignancy, Alan Waxman, MD, of Cedars-Sinai Medical Center, Los Angeles, said at a meeting on nuclear medicine sponsored by Johns Hopkins University.

BALTIMORE, Md--Both thallium-201 and technetium-99m are understudy as agents for use in examining breast lesions for malignancy,Alan Waxman, MD, of Cedars-Sinai Medical Center, Los Angeles,said at a meeting on nuclear medicine sponsored by Johns HopkinsUniversity.

Thallium-201 has shown good specificity and sensitivity in detectingpalpable breast lesions down to about 10 mm in size, the usuallimit for palpability. However, Dr. Waxman said, "while thalliumis useful in this range, it is just not good enough."

Dr. Waxman's study of technetium-99m methyoxyisobutyl isonitrile(MIBI) has shown some improvement in detecting abnormalities notvisible on thallium scans. Improved target-to-background ratio,he said, gives a slightly better sensitivity but also a slightlylower specificity. Nonetheless, lesions as small as 7 mm may bedetected with MIBI.

Magnetic resonance (MR) imaging can locate tumors down to 4 to5 mm in size, he said, but with less specificity (36% for MR imagingversus 81% for MIBI) due to a higher number of false positives.

Not a Screening Test

When using MIBI, Dr. Waxman employs a triple-headed camera toshorten imaging time to about 10 minutes. He suggests beginningimaging 5 minutes following MIBI injection. Tests on more than40 patients have shown little difference between a prone or supineposition of the patient, he said.

MIBI's sensitivity for nonpalpable lesions is dependent on size,and its specificity is fair to good for these lesions. For palpablelesions, MIBI has a negative predictive value of 98%, but, Dr.Waxman said, "I would still want to biopsy a woman with apalpable mass who was MIBI negative. It's a political and moralissue: You have to act on what is right in the medical world you'reliving in."

Dr. Waxman stressed that neither thallium nor MIBI breast imagingis a screening test. A mammogram and MIBI may disagree, and resolvingsuch discrepancies will not cut the number of biopsies and mayeven increase them.

Clinically, he said, the prime value of MIBI testing may lie inevaluating high-risk patients with inconclusive mammograms. Othergood candidates for MIBI are patients who have difficult-to-readmammograms due to prior radiation treatment and women who exhibitchanges in fibrocystic breasts.

Finally, he said, MIBI shows some potential use in planning thesurgical approach prior to lumpectomy.

Recent Videos
With many treatments emerging in the EGFR-mutated lung cancer landscape, sequencing therapy has emerged as a key consideration for these patients.
Although a greater risk of CNS relapse may emerge with immunotherapy-based backbones, toxicities associated with chemotherapy are avoided.
Current FDA expectations may allow patients to return to their community physicians at 2 weeks after administration of anitocabtagene autoleucel.
Based on its mechanism of action, anito-cel may cause fewer instances of cytokine release syndrome and delayed toxicities vs other therapies.
2 experts are featured in this series.
Once a patient-specific dose is determined, an all-oral combination of revumenib plus decitabine/cedazuridine and venetoclax may be “very good” in AML.
Related Content